6.1006.650 Cột Metrosep A Supp 7 - 250/2.0 METROHM

(1 đánh giá)

6.1006.650

Metrohm Thụy Sỹ

12 tháng

HSX: Metrohm Thụy Sỹ 

Ref # pn: 6.1006.650

Disinfection byproducts from water treatment are suspected not only of being health hazards but even of being carcinogenic. Oxyhalides have therefore become the subject of many investigations and standards (e.g., EPA 300.1 Part B, EPA 317.0, EPA 326.0)

 

Hotline: 0986.817.366 Mr.Việt

6.1006.650 Cột Metrosep A Supp 7 - 250/2.0 METROHM

HSX: Metrohm Thụy Sỹ

P/N: 6.1006.650

Disinfection byproducts from water treatment are suspected not only of being health hazards but even of being carcinogenic. Oxyhalides have therefore become the subject of many investigations and standards (e.g., EPA 300.1 Part B, EPA 317.0, EPA 326.0). Of primary concern is bromate, which forms from bromide during the ozonization of drinking water.
The microbore version of the Metrosep A Supp 7 - 250/4.0 is a high-performance separation column for the parallel determination of standard anions, oxyhalides and dichloroacetic acid. With this column, these ions are determined with certainty and precision down to the lower µg/L range. The high detection sensitivity is achieved through the use of the 5 µm polyvinyl alcohol polymer, with which extremely high plate numbers and thus outstanding separation and detection properties are achieved. In addition, the separation can be adapted to the specific requirements of the application by modifying the temperature.
This microbore column is particularly suitable for use with an MS detector.

Metrosep A Supp 7 - 250/2.0

 

Thông số kỹ thuật

Carrier material Polyvinyl alcohol with quarternary ammonium groups
Column capacity 27 µmol (Cl)
Column dimensions 250 x 2.0 mm
Eluents Carbonate eluent(standard eluent)

Sodium carbonate: 3.6 mmol/L; 763 mg/2 L
(column temperature: 45 °C)
Housing material PEEK
Max. pressure 20 MPa
Maximum flow 0.4 mL/min
Organic modifier 0 - 100% (particularly acetone, acetonitrile and methanol)
Particle size 5 µm
pH range 3–12
Standard flow 0.2 mL/min
Standard temperature 45 °C
Temperatur range 20–60 °C